-
Authentic Sine Wave Inverter – Provides clean, stable power for sensitive electronics.
-
Adaptive Charging – Optimizes charging efficiency with a four-stage adaptive process.
-
Hybrid PowerAssist Technology – Boosts capacity of generators or shore power by integrating battery support.
-
Versatile System Integration Features – Seamlessly integrates with various energy sources and systems.
-
Two AC Outputs with No-Break Functionality – Ensures continuous power for sensitive devices, with less than 20ms transition during grid failure.
-
Second Output Active When AC Input is Present – Prevents battery drain by using AC power for non-critical loads.
-
Virtually Limitless Power via Parallel Operation – Supports up to six units for virtually unlimited power capacity.
-
Three-Phase Capability – Achievable with three units for large-scale power applications.
-
Split-Phase Options (120-0-120 V) – Provides flexible power configurations for different applications.
-
Power Control – Prevents generator or shore supply overload by managing excess power for charging.
-
PowerAssist – Enhances alternative power sources by supplementing with battery power during peak demands.
-
Four-Stage Adaptive Charger – Provides efficient charging with fine-tuned stages for battery health.
MultiPlus 12/2000/80-50 120V VE.Bus (UL 458)
$1,194.59
-
Up to 6 MultiPluses can operate in parallel, delivering 15kW/12kVA output and 420A charging capacity.
-
Supports three-phase power setup with 3 units.
-
PowerControl limits charging current to prevent overloading shore or generator input.
-
PowerAssist supplements grid/generator power with battery during short peak demands.
-
Dual-bank charging with adaptive 4-stage algorithm for efficient battery maintenance.
-
Easy configuration via DIP switches for quick system adjustments post-installation.
Reliable Power, Instant Backup
The Victron Energy MultiPlus 12/2000/80-50 120V VE.Bus is a compact inverter/charger that combines pure sine wave output with smart battery charging and fast AC switching. It prevents overloads on limited power sources like generators or shore power, and ensures uninterrupted operation of sensitive electronics during outages with automatic switchover in under 20 milliseconds.
Dimensions | 506 × 236 × 147 in |
---|
Related products
MultiPlus 12/3000/120-50 120V VE.Bus (UL 1741 & 458)
-
Up to 6 MultiPluses can operate in parallel, delivering 15kW/12kVA output and 420A charging capacity.
-
Supports three-phase power setup with 3 units.
-
PowerControl limits charging current to prevent overloading shore or generator input.
-
PowerAssist supplements grid/generator power with battery during short peak demands.
-
Dual-bank charging with adaptive 4-stage algorithm for efficient battery maintenance.
-
Easy configuration via DIP switches for quick system adjustments post-installation.
MultiPlus Compact 12/2000/80-50 120V VE.Bus (UL 458)
-
wo AC outputs: Main output ensures seamless switch (<20ms); second output prevents unnecessary battery drain
-
Parallel operation: Connect up to 6 units for 15kW/18kVA output and 420A charging
-
PowerControl & PowerAssist: Manages generator/shore power limits and boosts short-term peak power with battery support
-
Three-phase support: Capable of delivering 3-phase power with 3 units
-
Adaptive 4-stage charger: Smart charging tailored to battery condition with dual bank support
-
Simple configuration: Quick setup with DIP switches and optional Multi-Control panel
MultiPlus-II 24/3000/70-50 120V (UL 458)
-
Power Assist – Prevents overloading of limited AC sources, automatically reducing battery charging, and boosting generator or shore power when needed.
-
Energy Storage System (ESS) – Essential for integrating with MPPT Solar Chargers or Grid-tie PV Inverters for efficient energy management.
-
Uninterrupted AC Power (UPS Function) – Provides seamless backup power within 20 milliseconds during grid or power source failures, ensuring continuous operation of sensitive electronics.
-
Remote Monitoring and Control – Allows local or remote monitoring and control via the GX device and free VRM app or portal, offering full system management from any device.
Phoenix Inverter 12/1200 120V VE.Direct NEMA 5-15R
-
VE.Direct communication supports Bluetooth Smart Dongle for easy connectivity
-
Reliable performance with full-bridge toroidal transformer design and overload protection
-
High start-up power for demanding devices like power tools and LED/halogen lamps
-
ECO mode saves energy by switching to standby during low loads and reactivating when needed
-
Remote control & LED diagnostics plus compatibility with Filax for fast switchover under 20ms
Quattro 12/5000/220-100/100 120V VE.Bus
-
Two AC Inputs with Integrated Transfer Switch – Connects to two independent AC sources and automatically switches to the active source.
-
Two AC Outputs – Main output with no-break functionality for sensitive electronics, second output only active when AC is available.
-
Split Phase and Three-Phase Capability – Supports up to 4 sets of 3 units in parallel, providing up to 96W/120kVA and 1600A charging.
-
PowerControl and PowerAssist – Optimizes generator/shore power use and supplements capacity with battery power during peak demand.
-
Solar-Powered Systems – Works in off-grid and grid-connected systems, ensuring AC power even during grid failure.
-
Easier System Configuration – Quick adjustments with DIP switches after installation for efficient setup.
Quattro-II 24/3000/70-50/50 2x120V
-
PowerControl and PowerAssist – Enhances the grid or generator capacity by managing energy usage and preventing overloads.
-
Two AC Inputs and Two AC Outputs – Allows connection to multiple power sources with efficient distribution of power.
-
Virtually Unlimited Power with Parallel and Three-Phase Operation – Scalable power output for larger systems, providing flexibility and high capacity.
-
On-Site System Configuring, Monitoring, and Control – Easy local management and adjustments of the system setup.
-
Remote Configuring and Monitoring – Full remote control and monitoring through internet connectivity for convenience and accessibility.