-
Authentic Sine Wave Inverter – Provides clean, stable power for sensitive electronics.
-
Adaptive Charging – Optimizes charging efficiency with a four-stage adaptive process.
-
Hybrid PowerAssist Technology – Boosts capacity of generators or shore power by integrating battery support.
-
Versatile System Integration Features – Seamlessly integrates with various energy sources and systems.
-
Two AC Outputs with No-Break Functionality – Ensures continuous power for sensitive devices, with less than 20ms transition during grid failure.
-
Second Output Active When AC Input is Present – Prevents battery drain by using AC power for non-critical loads.
-
Virtually Limitless Power via Parallel Operation – Supports up to six units for virtually unlimited power capacity.
-
Three-Phase Capability – Achievable with three units for large-scale power applications.
-
Split-Phase Options (120-0-120 V) – Provides flexible power configurations for different applications.
-
Power Control – Prevents generator or shore supply overload by managing excess power for charging.
-
PowerAssist – Enhances alternative power sources by supplementing with battery power during peak demands.
-
Four-Stage Adaptive Charger – Provides efficient charging with fine-tuned stages for battery health.
MultiPlus 12/2000/80-50 120V VE.Bus (UL 458)
-
Up to 6 MultiPluses can operate in parallel, delivering 15kW/12kVA output and 420A charging capacity.
-
Supports three-phase power setup with 3 units.
-
PowerControl limits charging current to prevent overloading shore or generator input.
-
PowerAssist supplements grid/generator power with battery during short peak demands.
-
Dual-bank charging with adaptive 4-stage algorithm for efficient battery maintenance.
-
Easy configuration via DIP switches for quick system adjustments post-installation.
MultiPlus 12/3000/120-50 120V VE.Bus (UL 1741 & 458)
-
Up to 6 MultiPluses can operate in parallel, delivering 15kW/12kVA output and 420A charging capacity.
-
Supports three-phase power setup with 3 units.
-
PowerControl limits charging current to prevent overloading shore or generator input.
-
PowerAssist supplements grid/generator power with battery during short peak demands.
-
Dual-bank charging with adaptive 4-stage algorithm for efficient battery maintenance.
-
Easy configuration via DIP switches for quick system adjustments post-installation.
MultiPlus 24/3000/70-50 120V VE.Bus (UL 1741 & 458)
-
Multifunctional with Intelligent Power Management – Provides efficient energy management for versatile applications.
-
One AC Input, Two AC Outputs – Ensures seamless power transfer, with the main output offering no-break functionality for sensitive devices.
-
Parallel Operation Capability – Supports up to 6 MultiPluses for virtually unlimited power, with 15kW/18kVA output and 420 amps charging capacity.
-
Three-Phase Power Supply – Achieved with 3 units, perfect for large-scale applications.
-
PowerControl – Prevents generator or shore supply overload by managing AC loads, ensuring safe battery charging.
-
PowerAssist – Supplements generator or shore power by using battery power during peak demand periods.
-
Four-Stage Adaptive Charger & Dual Bank Charging – Optimizes battery health with fine-tuned charging stages and supports dual bank charging.
-
Easier System Configuration – Simple setup and adjustments with DIP switch settings after installation.
MultiPlus Compact 12/2000/80-50 120V VE.Bus (UL 458)
-
wo AC outputs: Main output ensures seamless switch (<20ms); second output prevents unnecessary battery drain
-
Parallel operation: Connect up to 6 units for 15kW/18kVA output and 420A charging
-
PowerControl & PowerAssist: Manages generator/shore power limits and boosts short-term peak power with battery support
-
Three-phase support: Capable of delivering 3-phase power with 3 units
-
Adaptive 4-stage charger: Smart charging tailored to battery condition with dual bank support
-
Simple configuration: Quick setup with DIP switches and optional Multi-Control panel
MultiPlus-II 12/3000/120-50 120V (UL 458)
-
PowerAssist: Prevents overloading of AC sources like generators by adjusting battery charging and providing a power boost when necessary.
-
Uninterrupted AC Power (UPS Function): Provides seamless transition to battery power within 20 milliseconds during grid or power source failures, ensuring continuous operation of sensitive electronics.
-
Energy Storage Systems (ESS): Offers flexibility for integrating MPPT Solar Chargers and Grid-tie PV Inverters, making it ideal for solar energy and grid-tied power systems.
-
Solar Energy Solution: Works with both off-grid and grid-connected PV systems, ensuring uninterrupted power availability in solar energy setups.
-
Dual AC Outputs: Primary output for seamless power transfer during grid failures, while the second output is for non-battery-discharging loads (e.g., water heaters).
-
Parallel Operation & Flexibility: Supports parallel, split-phase, and three-phase configurations. Up to 6 units can be connected for higher power output and charging capacity.
-
On-Site Configuration & Monitoring: VEConfigure software simplifies on-site adjustments, making system configuration, monitoring, and control quick and easy.
-
Remote Access: Connects to the internet via Color Control GX for remote monitoring and control, enabling adjustments from anywhere via the Victron Remote Management (VRM) website.
MultiPlus-II 12/3000/120-50 2x120V (UL 458)
-
Two AC Outputs: Main output has no-break functionality with <20ms delay for seamless device switching. Second output activates only when AC is available, preventing unnecessary battery drain.
-
Parallel Operation: Up to 6 MultiPluses can run in parallel, providing 15kW/18kVA output and 420A of charging capacity.
-
Three-Phase Power: Requires 3 units to provide three-phase power supply.
-
PowerControl & PowerAssist: MultiPlus optimizes generator or shore power use, and supplements power from the battery during peak demands for limited periods.
-
Four-Stage Adaptive Charger: Automatically adjusts charging stages for optimal battery health, with float charge for long-term maintenance.
-
Easy Configuration & Remote Control: Simple system configuration with DIP switches and remote access through Ethernet for settings adjustments via Color Control GX or other GX devices.
MultiPlus-II 24/3000/70-50 120V (UL 458)
-
Power Assist – Prevents overloading of limited AC sources, automatically reducing battery charging, and boosting generator or shore power when needed.
-
Energy Storage System (ESS) – Essential for integrating with MPPT Solar Chargers or Grid-tie PV Inverters for efficient energy management.
-
Uninterrupted AC Power (UPS Function) – Provides seamless backup power within 20 milliseconds during grid or power source failures, ensuring continuous operation of sensitive electronics.
-
Remote Monitoring and Control – Allows local or remote monitoring and control via the GX device and free VRM app or portal, offering full system management from any device.
MultiPlus-II 24/3000/70-50 2x120V (UL 458)
-
PowerControl and PowerAssist – Enhances the grid or generator capacity by managing energy usage and preventing overloads.
-
Two AC Outputs – Provides reliable power distribution for connected devices.
-
Parallel and Three-Phase Operation – Supports scalable power output for virtually unlimited capacity.
-
On-Site Configuration, Monitoring, and Control – Enables easy system adjustments and monitoring at the installation site.
-
Remote Configuring and Monitoring – Allows full system control and monitoring remotely through the internet for convenient management.
Phoenix Inverter 12/1200 120V VE.Direct NEMA 5-15R
-
VE.Direct communication supports Bluetooth Smart Dongle for easy connectivity
-
Reliable performance with full-bridge toroidal transformer design and overload protection
-
High start-up power for demanding devices like power tools and LED/halogen lamps
-
ECO mode saves energy by switching to standby during low loads and reactivating when needed
-
Remote control & LED diagnostics plus compatibility with Filax for fast switchover under 20ms
Quattro 12/5000/220-100/100 120V VE.Bus
-
Two AC Inputs with Integrated Transfer Switch – Connects to two independent AC sources and automatically switches to the active source.
-
Two AC Outputs – Main output with no-break functionality for sensitive electronics, second output only active when AC is available.
-
Split Phase and Three-Phase Capability – Supports up to 4 sets of 3 units in parallel, providing up to 96W/120kVA and 1600A charging.
-
PowerControl and PowerAssist – Optimizes generator/shore power use and supplements capacity with battery power during peak demand.
-
Solar-Powered Systems – Works in off-grid and grid-connected systems, ensuring AC power even during grid failure.
-
Easier System Configuration – Quick adjustments with DIP switches after installation for efficient setup.